Finite Charged Rods: Changing the Observation Point
A finite straight rod is an excellent laboratory for learning electrostatic source integrals.
Its geometry is simple, but moving the observation point changes which electric-field
components survive and which antiderivatives are needed. The method must remain
consistent: identify a charge element, write its vector from source to observer, project
components, state bounds, and check a limiting case. This article develops five closely related
examples. The derivations apply to a prescribed stationary line density, not automatically
to an isolated metal rod in electrostatic equilibrium, whose surface charges generally
redistribute.
1 Geometry and the master source integral
A rod extends along the x axis from x′ = −L∕2 to x′ = +L∕2. Let the constant line charge density
be λ, with SI units C∕m; its total charge is Q = λL. Use r′ = x′x for the source coordinate and
r = x0x + ay for the observation coordinate, with a > 0 for the main derivation. The
source-to-observer vector is
A small element of length dx′ carries signed charge dq = λdx′. Coulomb’s law gives
Here ke = 1∕(4π𝜖0). The field is the vector integral of this expression over the original source
interval. The observation coordinates x0,a are held fixed while x′ changes. Never replace x′ with x0
inside the integrand.
Figure 1. A finite uniformly charged rod and a movable observation point. The separation vector
begins at a source element dq and ends at P, while x′ is the integration coordinate.
2 Worked example 1: the perpendicular bisector
Set x0 = 0. The x component contains an odd numerator −x′ while the denominator is even in x′.
The integral for Ex therefore vanishes because both the rod and its density are symmetric: Ex = 0.
The vertical field is
Figure 3. The substitution x′ = atan𝜃 comes from this right triangle, with a > 0 and |𝜃| < π∕2.
The hypotenuse explains the factor sec𝜃.
2.1 Complete trigonometric substitution
For a > 0, let x′ = a tan 𝜃. The differential and denominator transform as
The final equality is justified because the relevant substitution interval lies within −π∕2 < 𝜃 < π∕2,
where sec 𝜃 > 0. The lower and upper source limits become
Insert these expressions into the original integral, retaining its factor of a:
Because sin[arctan t] = t∕
for real t, the answer is
For positive density, the field points away from the rod. For negative density, it points toward the
rod. Both the sign and the units follow directly from the signed λ.
2.2 Two limiting checks
At a ≫ L, the square root in the denominator approaches a, and the field reduces to
keQ∕a2. The distant rod looks like a point charge of total charge Q = λL. At fixed
a > 0 and L →∞ with λ held fixed, the result approaches 2keλ∕a = λ∕(2π𝜖0a), the
magnitude for an infinite straight line. These are different limits: the first keeps total
finite charge fixed while moving away; the second increases total source charge without
bound.
3 Worked example 2: an arbitrary off-center observation point
Now allow x0≠0. Introduce u = x0 −x′, so du = −dx′. The old limits x′ = −L∕2 and +L∕2 become
u+ = x0 + L∕2 and u− = x0 − L∕2, respectively. After reversing limits, the components
are
For the first component, differentiate (u2 + a2)−1∕2:
Thus ∫
u(u2 + a2)−3∕2du = −(u2 + a2)−1∕2. For the second component, the earlier trigonometric
substitution or direct differentiation gives
Define the endpoint distances R± =
. Evaluation yields
When x0 = 0, the two endpoint distances agree, giving Ex = 0, while the second equation reduces
to the perpendicular-bisector formula. The endpoint denominators must be associated
with the correct signed numerator; interchanging just one endpoint commonly causes
errors.
Figure 2. Changing the observation point changes component cancellation. Above the midpoint
the horizontal components cancel. At a shifted observation point they generally do not.
4 Worked example 3: directly above the right endpoint
Set x0 = L∕2 and keep a > 0. Then u− = 0 and u+ = L. Equations (11) and (12) give
Both components are positive for a positively charged rod. This follows from the geometry: all
source elements lie at or to the left of the observation point and below it. For a ≫ L, the rod again
looks like a single charge, but the point-charge direction is referenced to the rod’s midpoint rather
than its endpoint.
5 Worked example 4: on the rod axis beyond an endpoint
Let the observation point be P = (x0, 0) with x0 > L∕2. All source-to-observer vectors are positive
multiples of x; the field has no transverse component. Coulomb’s law becomes
The result is finite for x0 > L∕2 and diverges as the ideal observation point approaches an endpoint
from outside. The field approaches keλL∕x02 far from the rod. It would be incorrect to substitute
a = 0 blindly into Equation (12): that expression was derived for a > 0 and contains a removable
or singular form depending on observation position.
6 Worked example 5: derive the electric potential and recover both field components
Choose V (∞) = 0. Because potential is scalar,
With u = x0 − x′ and reversed limits, use ∫
du∕
= arsinh(u∕a) for a > 0:
Differentiate with respect to x0 while holding a fixed. Since d arsinh(u∕a)∕du = 1∕
,
To obtain Ey, differentiate with respect to a while holding x0 fixed. For any fixed u,
It follows that
This independent check recovers both components and establishes consistency between the scalar
and vector source integrations.
7 Worked example 6: a simple nonuniform density and the danger of false symmetry
Suppose the rod’s density is now λ(x′) = λ0(1 + x′∕L) on −L∕2 ≤ x′≤ L∕2. The geometry is
symmetric about x′ = 0, but the charge distribution is not. At x0 = 0, the horizontal field
becomes
The uniform-density part cancels, while the gradient contribution is negative and survives.
Consequently a midpoint observation point does not guarantee zero horizontal field. The fully
evaluated version of this phenomenon appears in ES02E5.
8 Common mistakes and checks
- The source coordinate x′ moves across the rod; x0 and a describe the fixed observation
point.
- The substitution u = x0 − x′ reverses integration limits because du = −dx′.
- A symmetry cancellation requires the complete charge density to have the required
symmetry, not simply the mechanical support.
- The point-charge limit applies at distances large compared with L. It is not an accurate
approximation at distances comparable with the rod length.
- The expression
= a| sec 𝜃| becomes a sec 𝜃 only after we specify the interval
for 𝜃 and assume a > 0.
9 Exercises
- A rod extends from −0.10 to +0.10 m, with λ = 2.0 nC∕m. Find the field on the
bisector 0.10 m above its center.
- For a uniformly charged rod, find Ex and Ey at the point (L∕2,L), expressing the
answers in terms of keλ∕L.
- A uniform rod is extended while λ is held fixed. What does its bisector field approach
as L →∞?
- On the axial extension at x0 = L, simplify the field and identify its direction for λ > 0.
- Explain why a Conductor with a nonuniform surface charge distribution cannot
generally be modeled using a fixed uniform line density.
10 Complete exercise solutions
- Here L = 0.20 m, a = 0.10 m. Equation (7) gives Ey = ke(2.0 ×
10−9)(0.20)∕[0.10
] ≃ 254 N∕C, upward.
- With a = L and x0 = L∕2, Ex = (keλ∕L)(1 − 1∕
) and Ey = (keλ∕L)(1∕
), both
positive.
- At fixed a and λ, the result tends to 2keλ∕a = λ∕(2π𝜖0a), the field of an infinite line.
- Substitute x0 = L: Ex = keλ[(L∕2)−1 − (3L∕2)−1] = 4k
eλ∕(3L), along positive x.
- A conductor’s mobile charges redistribute until its surface satisfies the electrostatic
boundary conditions. Without the resulting density, prescribing a uniform value is an
additional physical assumption, not a consequence of the rod’s shape.
References
References
[1] D. J. Griffiths, Introduction to Electrodynamics, 4th ed., sections on electric fields and
potentials.
[2] E. M. Purcell and D. J. Morin, Electricity and Magnetism, 3rd ed., chapters on
electrostatics.
[3] MIT Open Learning Library, 8.02.1x Electricity and Magnetism: Electrostatics.
[4] PhysicsLibrary, Electric Dipoles and Continuous Charge Distributions (ES02).